fix(ceph): pin SATA link power to max_performance on OSD nodes (#347)
* fix(ceph): pin SATA link power to max_performance on OSD nodes * feat(ceph): drift-check the SATA link power management policy
This commit is contained in:
+39
-1
@@ -1,5 +1,5 @@
|
||||
---
|
||||
# Drift detection — compares expected Ansible state against live cluster.
|
||||
# Drift detection: compares expected Ansible state against live cluster.
|
||||
# Read-only. No changes. Reports mismatches.
|
||||
#
|
||||
# Usage:
|
||||
@@ -113,6 +113,44 @@
|
||||
== ceph_ssd_scheduler
|
||||
}] }}
|
||||
|
||||
# SATA link power management
|
||||
# Every AHCI port matters here, not a representative one: a single port
|
||||
# back on min_power_with_partial is enough to stall an OSD, so report the
|
||||
# distribution when the ports disagree.
|
||||
- name: Check SATA link power management policy
|
||||
ansible.builtin.shell: |
|
||||
set -o pipefail
|
||||
GLOB=/sys/class/scsi_host/host*/link_power_management_policy
|
||||
DISTINCT=$(cat $GLOB 2>/dev/null | sort -u | grep -c .)
|
||||
if [ "$DISTINCT" -eq 0 ]; then
|
||||
# No LPM-capable ports (SAS controllers expose scsi_host without the
|
||||
# attribute). The role skips these too, so there is nothing to drift.
|
||||
echo n/a
|
||||
elif [ "$DISTINCT" -eq 1 ]; then
|
||||
cat $GLOB 2>/dev/null | sort -u
|
||||
else
|
||||
cat $GLOB 2>/dev/null | sort | uniq -c \
|
||||
| awk '{printf "%s=%s ", $2, $1}' | sed 's/^/mixed: /; s/ $//'
|
||||
fi
|
||||
args:
|
||||
executable: /bin/bash
|
||||
register: sata_lpm
|
||||
changed_when: false
|
||||
when: ceph_sata_link_pm_enabled | bool
|
||||
|
||||
- name: Record SATA link power management drift
|
||||
ansible.builtin.set_fact:
|
||||
drift_results: >-
|
||||
{{ drift_results + [{
|
||||
'category': 'hardware',
|
||||
'item': 'SATA link power mgmt',
|
||||
'expected': ceph_sata_link_pm_policy,
|
||||
'actual': sata_lpm.stdout | trim | default('n/a'),
|
||||
'match': (sata_lpm.stdout | trim | default('n/a'))
|
||||
in [ceph_sata_link_pm_policy, 'n/a']
|
||||
}] }}
|
||||
when: ceph_sata_link_pm_enabled | bool
|
||||
|
||||
# nftables
|
||||
- name: Check nftables policy
|
||||
ansible.builtin.shell: |
|
||||
|
||||
@@ -11,7 +11,7 @@ ceph_ssd_scheduler: none
|
||||
ceph_hdd_readahead_kb: 4096 # 4 MB
|
||||
ceph_ssd_readahead_kb: 128 # 128 KB (kernel default)
|
||||
|
||||
# nr_requests (disk queue depth) — 0 means leave at kernel default
|
||||
# nr_requests (disk queue depth); 0 means leave at kernel default
|
||||
ceph_hdd_nr_requests: 128
|
||||
ceph_ssd_nr_requests: 0 # NVMe/SSD defaults are fine
|
||||
|
||||
@@ -19,6 +19,22 @@ ceph_ssd_nr_requests: 0 # NVMe/SSD defaults are fine
|
||||
# BlueStore manages discard for OSD devices internally.
|
||||
ceph_enable_fstrim_timer: true
|
||||
|
||||
# SATA link power management (ALPM).
|
||||
#
|
||||
# The AMD FCH AHCI ports come up as min_power_with_partial, which lets the SATA
|
||||
# PHY drop into Partial/Slumber between I/Os. Waking it costs milliseconds, and
|
||||
# on 2026-07-24 that surfaced as a BlueStore slow-op alert on osd.155 (curtis
|
||||
# sdk): PHYRdyChg/CommWake in dmesg, drive itself healthy.
|
||||
#
|
||||
# An OSD HDD is never idle enough for the power saving to be worth the wake
|
||||
# latency, so pin the link to max_performance. Applied live and persisted via
|
||||
# the same udev rules file as the block-device tuning.
|
||||
#
|
||||
# NOTE: writing this attribute schedules a libata EH cycle on the port, so roll
|
||||
# it out per node (serial: 1) rather than fleet-wide in one pass.
|
||||
ceph_sata_link_pm_enabled: true
|
||||
ceph_sata_link_pm_policy: max_performance
|
||||
|
||||
# Transparent Huge Pages -- madvise is universally correct for BlueStore.
|
||||
# THP=always drives tcmalloc/BlueStore RSS bloat and allocation-stall latency.
|
||||
# Applied on all ceph clusters (not gated behind the CPU governor).
|
||||
@@ -26,13 +42,13 @@ ceph_thp_enabled: true
|
||||
ceph_thp_mode: madvise # /sys/kernel/mm/transparent_hugepage/enabled
|
||||
ceph_thp_defrag: madvise # /sys/kernel/mm/transparent_hugepage/defrag
|
||||
|
||||
# CPU governor — force performance mode (disables power saving C-states)
|
||||
# CPU governor: force performance mode (disables power saving C-states)
|
||||
# Useful for dedicated Ceph nodes where latency matters more than power.
|
||||
ceph_cpu_governor_enabled: false
|
||||
ceph_cpu_governor: performance
|
||||
ceph_cpu_max_cstate: 1 # kernel param processor.max_cstate
|
||||
|
||||
# LVM device filter — restrict LVM scanning to known VGs.
|
||||
# LVM device filter: restrict LVM scanning to known VGs.
|
||||
# Prevents LVM from scanning raw OSD disks (speeds up lvscan/pvscan).
|
||||
ceph_lvm_filter_enabled: false
|
||||
ceph_lvm_filter: '[ "a|/dev/vg0/.*|", "a|/dev/md.*|", "r|.*|" ]'
|
||||
|
||||
@@ -77,6 +77,30 @@
|
||||
state: started
|
||||
when: ceph_enable_fstrim_timer | bool
|
||||
|
||||
# ---------- SATA link power management ----------
|
||||
|
||||
# The udev rule above covers boot and hot-plug; this applies the policy to
|
||||
# ports that are already up. Writing the attribute schedules a libata EH cycle
|
||||
# on that port, which is why this role wants serial: 1 on a serving cluster.
|
||||
- name: Set SATA link power management policy live
|
||||
ansible.builtin.shell: |
|
||||
set -uo pipefail
|
||||
POLICY="{{ ceph_sata_link_pm_policy }}"
|
||||
CHANGED=0
|
||||
for f in /sys/class/scsi_host/host*/link_power_management_policy; do
|
||||
[ -w "$f" ] || continue
|
||||
CUR=$(cat "$f" 2>/dev/null || echo "")
|
||||
if [ "$CUR" != "$POLICY" ]; then
|
||||
echo "$POLICY" > "$f" 2>/dev/null && CHANGED=1 || true
|
||||
fi
|
||||
done
|
||||
[ "$CHANGED" -eq 0 ] || echo CHANGED
|
||||
args:
|
||||
executable: /bin/bash
|
||||
register: _sata_lpm
|
||||
changed_when: "'CHANGED' in (_sata_lpm.stdout | default(''))"
|
||||
when: ceph_sata_link_pm_enabled | bool
|
||||
|
||||
# ---------- Transparent Huge Pages ----------
|
||||
|
||||
- name: Set Transparent Huge Pages live
|
||||
@@ -207,6 +231,22 @@
|
||||
register: scheduler_verify
|
||||
changed_when: false
|
||||
|
||||
- name: Verify SATA link power management policy
|
||||
ansible.builtin.shell: |
|
||||
set -uo pipefail
|
||||
echo "=== SATA link power management ==="
|
||||
for f in /sys/class/scsi_host/host*/link_power_management_policy; do
|
||||
[ -e "$f" ] || continue
|
||||
cat "$f"
|
||||
done | sort | uniq -c | sed 's/^/ /'
|
||||
args:
|
||||
executable: /bin/bash
|
||||
register: sata_lpm_verify
|
||||
changed_when: false
|
||||
when: ceph_sata_link_pm_enabled | bool
|
||||
|
||||
- name: Display disk tuning state
|
||||
ansible.builtin.debug:
|
||||
msg: "{{ scheduler_verify.stdout_lines }}"
|
||||
msg: >-
|
||||
{{ scheduler_verify.stdout_lines
|
||||
+ (sata_lpm_verify.stdout_lines | default([])) }}
|
||||
|
||||
@@ -1,4 +1,4 @@
|
||||
# Ceph disk tuning udev rules — managed by Ansible (hardware-tuning role)
|
||||
# Ceph disk tuning udev rules, managed by Ansible (hardware-tuning role)
|
||||
# Applied on device add/change events. Survives reboots and hot-plug.
|
||||
|
||||
# HDD: rotational devices
|
||||
@@ -14,3 +14,11 @@ ACTION=="add|change", SUBSYSTEM=="block", ATTR{queue/rotational}=="0", ATTR{queu
|
||||
{% if ceph_ssd_nr_requests > 0 %}
|
||||
ACTION=="add|change", SUBSYSTEM=="block", ATTR{queue/rotational}=="0", ATTR{queue/nr_requests}="{{ ceph_ssd_nr_requests }}"
|
||||
{% endif %}
|
||||
{% if ceph_sata_link_pm_enabled %}
|
||||
|
||||
# SATA link power management: keep the PHY out of Partial/Slumber. Waking it
|
||||
# costs milliseconds and shows up as a BlueStore slow op, and an OSD disk is
|
||||
# never idle long enough for the saving to be worth it.
|
||||
# TEST== guards non-SATA hosts, which have no such attribute.
|
||||
ACTION=="add|change", SUBSYSTEM=="scsi_host", KERNEL=="host*", TEST=="link_power_management_policy", ATTR{link_power_management_policy}="{{ ceph_sata_link_pm_policy }}"
|
||||